ȸ¿ø°¡ÀÔ | ID/PW ã±â
Tel : 032-614-9414-5

 Æѽº 032-614-9416

 010-6313-2379

 apcmall@naver.com
ÀüÈ­:032-614-9414
ÀüÈ­:032-614-9415
Æѽº:032-614-9416
E-mail ¹®ÀÇ
apcmall@naver.com
  E-mail ¹®ÀÇ
±â¾÷ÀºÇà296-095325-01-011
¿¹±ÝÁÖ:(ÁÖ)¿¡ÀÌÇǾ¾¸ô´åÄÄ
 
 
1 (Áß°í)¿¡ÀÌÇǾ¾¸ô´åÄÄ¿¡¼­
 
2 (Áß°í)¿¡ÀÌÇǾ¾¸ô´åÄÄ¿¡¼­
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
EATON UPS > Eaton5P½Ã¸®Áî > Eaton 5P850GR/
850VA[600W]
EATON UPS
Eaton 5P850GR/
850VA[600W]
Á¦Á¶È¸»ç : EATON
ÆǸŰ¡°Ý : °ßÀû¹®ÀÇ
¼ö·® EA
 
     
  
»óÇ° »ó¼¼ ¼³¸í
 

 

±â¼ú»ç¾ç

5P850G(GR)

5P1150G(GR)

5P1550G(GR)

Á¤°Ý (VA / W)

850VA / 600W

1150VA / 770W

1550VA / 1100W

񃬣

Ÿ¿ö ¶Ç´Â ·¢ 1U

Ÿ¿ö ¶Ç´Â ·¢ 1U

Ÿ¿ö ¶Ç´Â ·¢ 1U

Àü±âÀû Ư¼º

 

񃬣

¶óÀÎ ÀÎÅÍ·ºÆ¼ºê(Line-interactive)

¹èÅ͸® ¹Ì»ç¿ë½ÃÀÔ·ÂÀü¾Ð ¹× ÁÖÆļö´ë

160V~294V(150V~294V·Î Á¶Àý °¡´É) 47~70Hz(50Hz ½Ã½ºÅÛ),56.5~70Hz(60Hz ½Ã½ºÅÛ), 40Hz Àú¹Î°¨ ¸ðµå

Ãâ·Â Àü¾Ð ¹× ÁÖÆļö

230V(+6/-10%)(200V/208V/220V/230V/240V·Î Á¶Àý °¡´É)50/60Hz +/- 0.1%(ÀÚµ¿ °¨Áö)

¿¬°á

 

ÀÔ·Â

 

Ãâ·Â - Ÿ¿ö ¸ðµ¨

IEC C13(10A) ¼ÒÄÏ 6°³

IEC C13(10A) ¼ÒÄÏ 8°³

IEC C13(10A) ¼ÒÄÏ 8°³

Ãâ·Â - ·¢ 1U ¸ðµ¨

IEC C13(10A) ¼ÒÄÏ 4°³

IEC C13(10A) ¼ÒÄÏ 6°³

IEC C13(10A) ¼ÒÄÏ 6°³

¹èÅ͸®

 

50%, 70% ºÎÇÏÀÏ ¶§ ¹é¾÷ ½Ã°£

¹é¾÷ ½Ã°£

12/7ºÐ

12/7ºÐ

13/8ºÐ

¹èÅ͸® °ü¸®

ABM¢ç ¹× ¿Âµµ º¸»ó ÃæÀü¹ý(»ç¿ëÀÚ ¼±Åà °¡´É), ÀÚµ¿ ¹èÅ͸® Å×½ºÆ®,°ú¹æÀü º¸È£

ÀÎÅÍÆäÀ̽º

 

Åë½Å Æ÷Æ®

USBÆ÷Æ® 1°³ + RS232 ½Ã¸®¾óÆ÷Æ® 1°³,¸±·¹ÀÌ Á¢Á¡(USB¿Í RS232 Æ÷Æ®´Â µ¿½Ã¿¡ »ç¿ëÇÒ ¼ö ¾øÀ½)

+ ¿ø°Ý ON/OFF ¹× ¿ø°Ý Àü¿ø OFF¿ë ¹Ì´Ï Å͹̳Πºí·Ï 1°³

Åë½Å Ä«µå ½½·Ô

³×Æ®¿öÅ©/ModBus/¸±·¹ÀÌ MS Ä«µå¿ë ½½·Ô 1°³

ÀÛµ¿ Á¶°Ç, ±âÁØ ¹× ½ÂÀÎ

ÀÛµ¿ ¿Âµµ

0~35¡ÆC

0~35¡ÆC

0~35¡ÆC

¼ÒÀ½ ¼öÁØ

< 40dB

< 40dB

< 40dB

¾ÈÀü

IEC/EN 62040-1, UL 1778

EMC, ¼º´É

IEC/EN 62040 -2 , IEC/EN 62040-3(¼º´É)

½ÂÀÎ

CE, CB º¸°í¼­(TUV)

±Ô°Ý H x W x D / Áß·®

Ÿ¿ö ¸ðµ¨ ±Ô°Ý

230 x 150 x 345mm

230 x 150 x 345mm

230 x 150 x 445mm

Ÿ¿ö ¸ðµ¨ Áß·®

10.4kg

11.1kg

15.6kg

·¢ 1U ¸ðµ¨ ±Ô°Ý

43.2 x 438 x 509mm

43.2 x 438 x 509mm

43.2 x 438 x 554mm

·¢ 1U ¸ðµ¨ Áß·®

13.8kg

14.6kg

19.4kg



ÀÌÆ° 5P 850i VA ·¢ 1U
 
ÀϹÝ
ÅäÆú·ÎÁö ¶óÀÎ ÀÎÅÍ·¢Æ¼ºê °íÁÖÆÄ (¼ø¼ö Á¤ÇöÆÄ, ºÎ½ºÅÍ + ÆäÀÌ´õ)
±¸¼º 1U ·¢
ºÎÇ° ¹øÈ£ 5P850GR
Æò°¡ (VA / ¿ÍÆ®) 600VA /850 W
Å©±â (³ôÀÌ x °¡·Î x ¼¼·Î, mm) 43.2 X 438 X 509
¹«°Ô (kg) 13.8
º¸Áõ 2 ³â
 
Àü±â ÀÔ·Â
¿¬°á
(1) IEC-320-C14
C14
¹èÅ͸®¸¦ »ç¿ëÇÏÁö ¾Ê°í ÀÔ·Â Àü¾Ð 160V-294V (1​​50V-294V·Î Á¶Á¤ °¡´É)
¹èÅ͸®¸¦ »ç¿ëÇÏÁö ¾Ê°í ÀÔ·Â ÁÖÆļö ¹üÀ§ 47 70Hz¿¡¼­ (50 Hz¿¡¼­ ½Ã½ºÅÛ), 70Hz¿¡¼­ 56.5 (60 Hz¿¡¼­ ½Ã½ºÅÛ), ³·Àº °¨µµ ¸ðµå¿¡¼­ 40Hz¿¡¼­¿¡
 
Àü±â Ãâ·Â
Àü¾Ð 230 V (+6 / -10 %) (200V / 208V / 220V / 230V / 240V·Î Á¶Á¤)
Ãâ·Â ¸®¼ÁÅÍŬ
(4) IEC-320-C13
C13
¿ø°Ý Á¦¾î ¼ÒÄÏ 2 °³ IEC C13ÀÇ 2 °³ ±×·ì (10)
Ãâ·Â ÁÖÆļö 50 / 60 Hz¿¡¼­ + / - 0.1 % (ÀÚµ¿ °¨Áö)
 
¹èÅ͸®   Á¤Àüº¸»ó½Ã°£ 600W »ç¿ë½Ã4ºÐ  / 300W »ç¿ë½Ã12ºÐ
¹èÅ͸® °ü¸® ABM ¢ç ¹× ¿Âµµ (¼±ÅÃ)¸¦ À§Å¹ ¹æ¹ý º¸Á¤, ÀÚµ¿ ¹èÅ͸® Å×½ºÆ®, ±íÀº Ãâ·Â º¸È£
 
Åë½Å
Åë½Å Æ÷Æ® 1 USB Æ÷Æ® + 1 RS232 ½Ã¸®¾ó Æ÷Æ® ¹× ¸±·¹ÀÌ Á¢Á¡ (USB ¹× RS232 Æ÷Æ®¸¦ µ¿½Ã¿¡ »ç¿ëÇÒ ¼ö ¾ø½À´Ï´Ù), ¿ø°Ý ON / OFF ¹× ¿ø°Ý Àü¿ø ²ô±â 1 ¹Ì´Ï Å͹̳Πºí·Ï
Åë½Å Ä«µå ½½·Ô ³×Æ®¿öÅ© MS Ä«µå, ¸ðµå ¹ö½º-MS ¶Ç´Â ¸±·¹ÀÌ MS Ä«µå ½½·Ô 1 °³
 
ȯ°æ ¹× Ç¥ÁØ
¼ÒÀ½ <40 dBAÀÇ
ÀÛµ¿ ¿Âµµ 0 ~ 35 ¡Æ C
¾ÈÀü Ç¥½Ã IEC / EN 62040-1, UL 1778
EMC ¸¶Å© IEC / EN 62040-2, IEC / EN 62040-3 (¼º´É)
½ÂÀÎ CE, CB º¸°í¼­, TÜV

¿µ¹®»ç¾ç¼­

5P850GR




Eaton 5P 850i VA Rack 1U
 
General
ÅäÆ÷·ÎÁö Line-Interactive High Frequency (Pure Sinewave, Booster + Fader)
±¸¼º Rack 1U
ÆÄÆ® ¹øÈ£ 5P850GR
¿ë·® 850VA/600W
Å©±â H x W x D mm 43.2 x 438 x 509
Áß·®(Kg) 13.8
º¸Áõ  2 years
 
Electrical Input
¿¬°á
(1) IEC-320-C14
C14
¹èÅ͸® ¹Ì»ç¿ë ½Ã ÀÔ·Â Àü¾Ð 160V-294V (adjustable to 150V-294V)
¹èÅ͸® ¹Ì»ç¿ë ½Ã ÀÔ·Â ÁÖÆļö´ë¿ª 47 to 70Hz (50 Hz system), 56.5 to 70Hz (60 Hz system), 40Hz in low-sensitivity mode
 
Electrical Output
Àü¾Ð 230 V (+6/-10 %) (Adjustable to 200V / 208V / 220V / 230V / 240V)
Ãâ·Â Äܼ¾Æ®
(4) IEC-320-C13
C13
¿ø°Ý Á¦¾î ¼ÒÄÏ 2 groups of 2 x IEC C13 (10 A)
Ãâ·Â ÁÖÆļö 50/60 Hz +/- 0.1 % (autosensing)
¹èÅ͸® °ü¸® ABM¢ç & temperature compensated charging method (user selectable), automatic battery test, deep discharge protection
 
Communications
°¡Ã» °æº¸ 1 USB port + 1 RS232 serial port and relay contacts (USB and RS232 ports cannot be used simultaneously), 1 mini-terminal block for remote ON/OFF and Remote Power Off
Åë½Å ½½·Ô 1 slot for Network-MS card, ModBus-MS or Relay-MS cards
 
Environmental & Standards
¿­ ¹ß»ê(BTU) < 40 dBA
°¡Ã» ¼ÒÀ½ 0 to 35¡ÆC
Standards and Compliance IEC/EN 62040-1, UL 1778
Safety markings IEC/EN 62040-2, IEC/EN 62040-3 (performance)
Ç°Áú CE, CB report, TÜV
 
Physical
Bundled With In the interests of continuous product improvement all specifications are subject to change without notice.

* Á¤Àüº¸»ó½Ã°£
»ç¿ë·®:60W      ¹é¾÷½Ã°£:70ºÐ
»ç¿ë·®:120W     ¹é¾÷½Ã°£:33ºÐ
»ç¿ë·®:117W     ¹é¾÷½Ã°£:22ºÐ
»ç¿ë·®:253W     ¹é¾÷½Ã°£:15ºÐ
»ç¿ë·®:301W     ¹é¾÷½Ã°£:12ºÐ
»ç¿ë·®:321W     ¹é¾÷½Ã°£:11ºÐ
»ç¿ë·®:345W     ¹é¾÷½Ã°£:10ºÐ
»ç¿ë·®:374W     ¹é¾÷½Ã°£:9ºÐ
»ç¿ë·®:411W     ¹é¾÷½Ã°£:8ºÐ
»ç¿ë·®:461W     ¹é¾÷½Ã°£:7ºÐ
»ç¿ë·®:522W     ¹é¾÷½Ã°£:6ºÐ
»ç¿ë·®:575W     ¹é¾÷½Ã°£:5ºÐ
»ç¿ë·®:600W     ¹é¾÷½Ã°£:4ºÐ

 
 
 
»óÇ° »ç¿ë Èıâ
 
À̸§ :
³»¿ë :
ÆòÁ¡
 
 
 
 
»óÇ° QNA
 
»óÇ°¿¡ ´ëÇØ ±Ã±ÝÇÑ Á¡À» ÇØ°áÇØ µå¸³´Ï´Ù.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Á¶È¸
 
 
ȸ»ç¼Ò°³ | ÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ã³¸®¹æħ | ÀÌ¿ë¾È³»
»óÈ£ : ÁÖ½Äȸ»ç ¿¡ÀÌÇǾ¾¸ô´åÄÄ | ´ëÇ¥ÀÚ(¼º¸í):Á¤±â¿î l °³ÀÎÁ¤º¸ º¸È£ Ã¥ÀÓÀÚ : Á¤±â¿î
»ç¾÷ÀÚ µî·Ï¹øÈ£ ¾È³» 420-86-00644 [»ç¾÷ÀÚÁ¤º¸È®ÀÎ] | Åë½ÅÆǸž÷ ½Å°í¹øÈ£ : Á¦2017-°æ±âºÎõ-1469 È£
ÁÖ¼Ò: °æ±âµµ ºÎõ½Ã ¿ø¹Ì±¸ Á¶¸¶·ç·Î 122, 2610È£ (»ïº¸Å×Å©³ëŸ¿ö) | ÀüÈ­ : 032-614-9414-5,Æѽº 032-614-9416,010-6313-2379,apcmall@naver.com
Contact ¸ÞÀÏ for more information. Copyright ¨Ï apcmall.com ¿¡ÀÌÇǾ¾¸ô´åÄÄ All rights reserved.