ȸ¿ø°¡ÀÔ | ID/PW ã±â
Tel : 032-614-9414-5

 Æѽº 032-614-9416

 010-6313-2379

 apcmall@naver.com
ÀüÈ­:032-614-9414
ÀüÈ­:032-614-9415
Æѽº:032-614-9416
E-mail ¹®ÀÇ
apcmall@naver.com
  E-mail ¹®ÀÇ
±â¾÷ÀºÇà296-095325-01-011
¿¹±ÝÁÖ:(ÁÖ)¿¡ÀÌÇǾ¾¸ô´åÄÄ
 
 
1 (Áß°í)¿¡ÀÌÇǾ¾¸ô´åÄÄ¿¡¼­
 
2 (Áß°í)¿¡ÀÌÇǾ¾¸ô´åÄÄ¿¡¼­
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
EATON UPS > Eaton9SX½Ã¸®Áî > Eaton 9SX11KIRT/
11KVA[10KW]
EATON UPS
Eaton 9SX11KIRT/
11KVA[10KW]
Á¦Á¶È¸»ç : EATON
ÆǸŰ¡°Ý : °ßÀû¹®ÀÇ
¹èÅ͸®Æ÷ÇÔ
¼ö·® EA
 
     
  
»óÇ° »ó¼¼ ¼³¸í
 

 








Eaton 9SX 11K iRT6U/11KVA[10KW]
 
General
ÅäÆ÷·ÎÁö On-line double conversion with PFC (Power Factor Correction) system
±¸¼º Rack/Tower
ÆÄÆ® ¹øÈ£ 9SX11KiRT
¿ë·® 11000/10000
Å©±â H x W x D mm 440 x 260 x 700
Áß·®(Kg) 86
º¸Áõ 2 years on electronics and battery
 
Electrical Input
¿¬°á
Hardwired - see manual for terminal block layout
Hardwired - example layout only
Input Voltage Range 176-276V without derating (up to 100–276V with derating)
°øĪ Àü¾Ð 200/208/220/230/240/250V
Frequency 50/60 Hz autoselection
Frequency Range 40-70 Hz
¼ô ½áÅ°Æ® Àü·ù 150 A
THDI <5%
 
Electrical Output
Àü¾Ð 200/208/220/230/240/250V +/– 1%
Àü¾ÐTHD < 2%
Ãâ·Â Äܼ¾Æ®
Hardwired - see manual for terminal block layout
Hardwired - example layout only
°úºÎÇÏ ³»·® 102–110% : 120s, 110–125%: 60s, 125–150%: 10s, >150%: 900ms
È¿À²(Á¤»ó ¸ðµå) Up to 95% in Online mode, 98% in Hi-Efficiency mode
Ãâ·Â ÁÖÆļö 50/60 Hz autoselect, frequency converter as standard
ºÎÇÏ crest À² 3:1

¹èÅ͸® °ü¸® ABM¢ç and Temperature compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of external battery units.
ÃàÀüÁö ½ÃÇè EBM (3U)
Deep Discharge Protection Multilingual graphical LCD display
 
Communications
°¡Ã» °æº¸ 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously), 4 dry contacts (DB9), 1 mini terminal block for remote On/Off and 1 for remote power Off, 1 DB15 for parallel operation.
Relay Output 1 slot for Network-MS card, ModBus-MS or Relay-MS cards
 
Environmental & Standards
¿­ ¹ß»ê(BTU) <50dB
°¡Ã» ¼ÒÀ½ 0 to 40¡ÆC continuous
Standards and Compliance IEC/EN 62040-1, UL 1778, CSA 22.2
Safety markings IEC/EN 62040 -2 , FCC Class A, IEC/EN 62040-3 (Performance)
Ç°Áú CE, CB report (TUV), UL
 
Physical
Bundled With In the interests of continuous product improvement all specifications are subject to change without notice.
 
 
»óÇ° »ç¿ë Èıâ
 
À̸§ :
³»¿ë :
ÆòÁ¡
 
 
 
 
»óÇ° QNA
 
»óÇ°¿¡ ´ëÇØ ±Ã±ÝÇÑ Á¡À» ÇØ°áÇØ µå¸³´Ï´Ù.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Á¶È¸
 
 
ȸ»ç¼Ò°³ | ÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ã³¸®¹æħ | ÀÌ¿ë¾È³»
»óÈ£ : ÁÖ½Äȸ»ç ¿¡ÀÌÇǾ¾¸ô´åÄÄ | ´ëÇ¥ÀÚ(¼º¸í):Á¤±â¿î l °³ÀÎÁ¤º¸ º¸È£ Ã¥ÀÓÀÚ : Á¤±â¿î
»ç¾÷ÀÚ µî·Ï¹øÈ£ ¾È³» 420-86-00644 [»ç¾÷ÀÚÁ¤º¸È®ÀÎ] | Åë½ÅÆǸž÷ ½Å°í¹øÈ£ : Á¦2017-°æ±âºÎõ-1469 È£
ÁÖ¼Ò: °æ±âµµ ºÎõ½Ã ¿ø¹Ì±¸ Á¶¸¶·ç·Î 122, 2610È£ (»ïº¸Å×Å©³ëŸ¿ö) | ÀüÈ­ : 032-614-9414-5,Æѽº 032-614-9416,010-6313-2379,apcmall@naver.com
Contact ¸ÞÀÏ for more information. Copyright ¨Ï apcmall.com ¿¡ÀÌÇǾ¾¸ô´åÄÄ All rights reserved.